● Zero Transfer time
● DSP Digital Control Based
● Li-ion Battery Powered
● Dry Contact control lnterface for BMs
● ModBus interface with BMS
● Li-ion Battery Charger
● Ultra-wide Wide Input Mains range
● Best Loading Capability
● Genset Compatible
● High lnput power factor Reliable design
● Open to customization
● Ultra wide I/P voltage range;
● Clean power quality issues;
● Adapt to harsh power condition;
● Long back up time operation;
● Compatible with genset.
● Zero Transfer time
● DSP Digital Control Based
● Li-ion Battery Powered
● Dry Contact control lnterface for BMs
● ModBus interface with BMS
● Li-ion Battery Charger
● Ultra-wide Wide Input Mains range
● Best Loading Capability
● Genset Compatible
● High lnput power factor Reliable design
● Open to customization
● Ultra wide I/P voltage range;
● Clean power quality issues;
● Adapt to harsh power condition;
● Long back up time operation;
● Compatible with genset.
Applications
IT infrastructure: small server and workstation, router and switch, monitoring equipment;
Automation system: ATM, TVM, SCADA, Railway and Metro signal system;
Office and Business Equipment: PC, Printer, Scanner, POS, Telephones and Fax.
Specification
Model |
PX6KRL- LI |
PX10KRL- LI |
|
Rated power |
5KVA/4.5KW |
10KVA/9KW |
|
AC Input |
Input system |
Single phase (L/N+PE) |
|
Nominal voltage |
208/220/230/240VAC |
||
Frequency |
50/60Hz |
||
Voltage range |
90~300VAC |
||
Frequency range |
(40~70)±0.5Hz |
||
Input power factor |
>0.99 |
||
Battery Input |
Charging Voltage |
216V(default for 60cell of LiFePO4 ) / Customerized according to battery request |
|
Battery Capacity |
External |
||
Charger Behavior & Protection |
CC. CV. Floating. Turn-Off 4 states 3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface |
||
Charging Current |
Long Backup Time Model :4A / 8A (Optional) |
||
AC Output |
Output wiring system |
Single phase (L/N+PE) |
|
Inverter Output voltage |
208/220/230/240VAC±1% |
||
Waveform |
Sine Wave |
||
Harmonic Distortion |
THD<2% (linear load) THD<7% (nonlinear load) |
||
Output frequency |
50/60±4Hz (Sync mode) 50/60Hz±0.1% (Fix Freq. mode) |
||
Overload capability |
100%~105% continuous. 60Sec.@105%~130% Rated Load 10Sec.@130%~150% Rated Load 0.3Sec.@>150%Rated Load |
||
Transfer time |
Battery <-> Line Mode :0ms |
||
Efficiency |
Line Mode |
>92% |
>93% |
Battery Mode |
>90% |
||
Physical |
Chassis Style |
Rack-Mounted |
|
Rack Dimension W x H x D (mm) |
PX6KRL-LI/ PX 10KRL-LI: 440mm(W) x 88mm(2U)(H) x 500mm(D) |
||
Weight (kg) |
11.5kg |
13.5kg |
|
Standards COMMUNICATION |
RS232 PORT Network Card: Support SNMP,TCP/IP Protocol , for remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown Dry Contact Interface for BMS control ModBUS For BMS interface |
||
Alarm Function |
AC/DC input under abnormal, overload condition and Inverter problems |
||
Protection Function |
AC input or output above or below the range of voltage, overload, over temperature and short circuit protection |
||
Operating Environment Endurance |
Temperature range |
-10~50oC |
|
Relative Humidity |
0-98%(Non-condensing) |
||
Acoustics Noise |
<55dB @ 1 meters |
Model |
PX6KRL- LV- LI |
PX10KRL- LV- LI |
|
Rated power |
5KVA/4.5KW |
10KVA/9KW |
|
AC Input |
Input system |
Single phase (L/N+PE) |
|
Nominal voltage |
100/110/120/127Vac |
||
Frequency |
50/60Hz |
||
Voltage range |
60-145Vac±3VAC |
||
Frequency range |
(40~70)±0.5Hz |
||
Input power factor |
>0.99 |
||
Bypass Voltage Range |
80~140VAC×(1±3%) |
||
Battery Input |
Charging Voltage |
216V(default for 60cell of LiFePO4 ) / Customerized according to battery request |
|
Battery Capacity |
External |
||
Charger Behavior & Protection |
CC. CV. Floating. Turn-Off 4 states 3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface |
||
Charging Current |
Long Backup Time Model :4A / 8A (Optional) |
||
AC Output |
Output wiring system |
Single phase (L/N+PE) |
|
Inverter Output voltage |
100/110/120/127Vac±2% |
||
Waveform |
Sine Wave |
||
Harmonic Distortion |
THD<2% (linear load) THD<7% (nonlinear load) |
||
Output frequency |
50/60±4Hz (Sync mode) 50/60Hz±0.1% (Fix Freq. mode) |
||
Overload capability |
105~125%≥ 60s,126~150%≥30s The recover point is 70% |
||
Transfer time |
Battery <-> Line Mode :0ms |
||
Efficiency |
Line Mode |
>92% |
>93% |
Battery Mode |
>90% |
||
Physical |
Chassis Style |
Rack-Mounted |
|
Rack Dimension W x H x D (mm) |
PX6KRL-LV: 440(W) x 88(2U)(H) x 500(D)mm PX10KRL-LV: 440(W)x176(4U)(H)x530(D)mm |
||
Weight (kg) |
15.0kg |
26.1kg |
|
Standards COMMUNICATION |
RS232 PORT Network Card: Support SNMP,TCP/IP Protocol , for remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown Dry Contact Interface for BMS control ModBUS For BMS interface |
||
Alarm Function |
AC/DC input under abnormal, overload condition and Inverter problems |
||
Protection Function |
AC input or output above or below the range of voltage, overload, over temperature and short circuit protection |
||
Operating Environment Endurance |
Temperature range |
-10~50oC |
|
Relative Humidity |
0-98%(Non-condensing) |
||
Acoustics Noise |
<55dB @ 1 meters |
Applications
IT infrastructure: small server and workstation, router and switch, monitoring equipment;
Automation system: ATM, TVM, SCADA, Railway and Metro signal system;
Office and Business Equipment: PC, Printer, Scanner, POS, Telephones and Fax.
Specification
Model |
PX6KRL- LI |
PX10KRL- LI |
|
Rated power |
5KVA/4.5KW |
10KVA/9KW |
|
AC Input |
Input system |
Single phase (L/N+PE) |
|
Nominal voltage |
208/220/230/240VAC |
||
Frequency |
50/60Hz |
||
Voltage range |
90~300VAC |
||
Frequency range |
(40~70)±0.5Hz |
||
Input power factor |
>0.99 |
||
Battery Input |
Charging Voltage |
216V(default for 60cell of LiFePO4 ) / Customerized according to battery request |
|
Battery Capacity |
External |
||
Charger Behavior & Protection |
CC. CV. Floating. Turn-Off 4 states 3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface |
||
Charging Current |
Long Backup Time Model :4A / 8A (Optional) |
||
AC Output |
Output wiring system |
Single phase (L/N+PE) |
|
Inverter Output voltage |
208/220/230/240VAC±1% |
||
Waveform |
Sine Wave |
||
Harmonic Distortion |
THD<2% (linear load) THD<7% (nonlinear load) |
||
Output frequency |
50/60±4Hz (Sync mode) 50/60Hz±0.1% (Fix Freq. mode) |
||
Overload capability |
100%~105% continuous. 60Sec.@105%~130% Rated Load 10Sec.@130%~150% Rated Load 0.3Sec.@>150%Rated Load |
||
Transfer time |
Battery <-> Line Mode :0ms |
||
Efficiency |
Line Mode |
>92% |
>93% |
Battery Mode |
>90% |
||
Physical |
Chassis Style |
Rack-Mounted |
|
Rack Dimension W x H x D (mm) |
PX6KRL-LI/ PX 10KRL-LI: 440mm(W) x 88mm(2U)(H) x 500mm(D) |
||
Weight (kg) |
11.5kg |
13.5kg |
|
Standards COMMUNICATION |
RS232 PORT Network Card: Support SNMP,TCP/IP Protocol , for remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown Dry Contact Interface for BMS control ModBUS For BMS interface |
||
Alarm Function |
AC/DC input under abnormal, overload condition and Inverter problems |
||
Protection Function |
AC input or output above or below the range of voltage, overload, over temperature and short circuit protection |
||
Operating Environment Endurance |
Temperature range |
-10~50oC |
|
Relative Humidity |
0-98%(Non-condensing) |
||
Acoustics Noise |
<55dB @ 1 meters |
Model |
PX6KRL- LV- LI |
PX10KRL- LV- LI |
|
Rated power |
5KVA/4.5KW |
10KVA/9KW |
|
AC Input |
Input system |
Single phase (L/N+PE) |
|
Nominal voltage |
100/110/120/127Vac |
||
Frequency |
50/60Hz |
||
Voltage range |
60-145Vac±3VAC |
||
Frequency range |
(40~70)±0.5Hz |
||
Input power factor |
>0.99 |
||
Bypass Voltage Range |
80~140VAC×(1±3%) |
||
Battery Input |
Charging Voltage |
216V(default for 60cell of LiFePO4 ) / Customerized according to battery request |
|
Battery Capacity |
External |
||
Charger Behavior & Protection |
CC. CV. Floating. Turn-Off 4 states 3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface |
||
Charging Current |
Long Backup Time Model :4A / 8A (Optional) |
||
AC Output |
Output wiring system |
Single phase (L/N+PE) |
|
Inverter Output voltage |
100/110/120/127Vac±2% |
||
Waveform |
Sine Wave |
||
Harmonic Distortion |
THD<2% (linear load) THD<7% (nonlinear load) |
||
Output frequency |
50/60±4Hz (Sync mode) 50/60Hz±0.1% (Fix Freq. mode) |
||
Overload capability |
105~125%≥ 60s,126~150%≥30s The recover point is 70% |
||
Transfer time |
Battery <-> Line Mode :0ms |
||
Efficiency |
Line Mode |
>92% |
>93% |
Battery Mode |
>90% |
||
Physical |
Chassis Style |
Rack-Mounted |
|
Rack Dimension W x H x D (mm) |
PX6KRL-LV: 440(W) x 88(2U)(H) x 500(D)mm PX10KRL-LV: 440(W)x176(4U)(H)x530(D)mm |
||
Weight (kg) |
15.0kg |
26.1kg |
|
Standards COMMUNICATION |
RS232 PORT Network Card: Support SNMP,TCP/IP Protocol , for remote monitor the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown Dry Contact Interface for BMS control ModBUS For BMS interface |
||
Alarm Function |
AC/DC input under abnormal, overload condition and Inverter problems |
||
Protection Function |
AC input or output above or below the range of voltage, overload, over temperature and short circuit protection |
||
Operating Environment Endurance |
Temperature range |
-10~50oC |
|
Relative Humidity |
0-98%(Non-condensing) |
||
Acoustics Noise |
<55dB @ 1 meters |