SEARCH WHAT YOU WANT

PPS100W


It is composed of three-element circuit board, s2dc inverter circuit board and 3P battery protection circuit board. Inverter 100W correction wave AC220V/ 50Hz, subject to pure resistance load,USB port 5V/ 2A (total). It is suitable for camping, emergency communication,medical rescue, fire rescue and other fields.

It is composed of three-element circuit board, s2dc inverter circuit board and 3P battery protection circuit board. Inverter 100W correction wave AC220V/ 50Hz, subject to pure resistance load,USB port 5V/ 2A (total). It is suitable for camping, emergency communication,medical rescue, fire rescue and other fields.


Previous page: No more
Next page: No more
Product Details

Precautions for Product Operation

Strictly follow the operation steps of the product.

● For the heat dissipation space of the product, 5cm space is reserved around the product to make the heat dissipation convective.

● When the power of the product is insufficient, the load power exceeds the rated power or the ambient temperature is too high, the product will automatically start the protection function and turn off the output.

● For power charging, it is recommended to charge without load.

● If the power supply is not used for a long time, the power supply itself will be exhausted. Please make sure to charge it every 6 months.

● It is forbidden to use this product in flammable, explosive and corrosive gas environment such as gasoline and gas.

● If the product is accidentally flooded or invaded by other foreign substances, please send it to the Distribution Office for testing and treatment as soon as possible to ensure the safe use of the product. If it is caused by abnormal use, the company will charge for treatment according to the actual situation.

Specification

Model

PPS100

Capacity

5000m A h * 3 Series 2 parallel

Cell

21700/4000mA h 0.5C

B attery Power

88W H

A C Power

Correction wave A C 220V / 50H z

A C Peak V alue

200W peak maintenance time < 50ms

Conversion Eff i ciency

85% ≤

Class

Project

Specifications

INTPU T

D C input

PD bidirectional 20V / 3A 60W

ACOUT 220V

A C output voltage

1 A C socket A C220V ±  5%

A C output power

100W

A C output over power protection

A bout 120W

A C output waveform

Correction wave

A C output peak

200W peak maintenance time < 50ms

Frequency

50H z

USB output port

U sb1 output

5V /2A (Total3

U SB 2 output

QC3.0 M A X 12V /1.5A

Electric core

type

Ternary l i thium cell 21700 / 4000m A h

capacity

24000m A H (3S2P)

power

88WH

cycle l i fe

M ore than 1000 times

Charging parameters

 

PD 60W

Charging time

2.5-3.5H

Charge f rom 0% to 100% (automatic cut-off)

Full voltage

12.55V ± 0.1V

The battery i s charged to the voltage at automatic cut-off

LCD display

D i splay the power, charge and stop charge status

The power column f lashes, PD + in, and the power

column i s always on

D C, A C and inverter status

Switch status of U SB QC 3.0 and A C

Static self power consumption

 

<700uA

 

No load sleep

A C no load

The AC output will be automatically turned off after 1 minute

D C no load

When the AC i s not turned on, it will automatically enter sleep for one minute

Protection function

 

Short circuit, overload, overtemperature, overvoltage, overcurrent, undervoltage, etc

 

The display will flash three times and turn off the AC symbol

I nverter over temperature protection

Over temperature protection

≥ 100℃

Over temperature recovery

≤ 80℃

Precautions for Product Operation

Strictly follow the operation steps of the product.

● For the heat dissipation space of the product, 5cm space is reserved around the product to make the heat dissipation convective.

● When the power of the product is insufficient, the load power exceeds the rated power or the ambient temperature is too high, the product will automatically start the protection function and turn off the output.

● For power charging, it is recommended to charge without load.

● If the power supply is not used for a long time, the power supply itself will be exhausted. Please make sure to charge it every 6 months.

● It is forbidden to use this product in flammable, explosive and corrosive gas environment such as gasoline and gas.

● If the product is accidentally flooded or invaded by other foreign substances, please send it to the Distribution Office for testing and treatment as soon as possible to ensure the safe use of the product. If it is caused by abnormal use, the company will charge for treatment according to the actual situation.

Specification

Model

PPS100

Capacity

5000m A h * 3 Series 2 parallel

Cell

21700/4000mA h 0.5C

B attery Power

88W H

A C Power

Correction wave A C 220V / 50H z

A C Peak V alue

200W peak maintenance time < 50ms

Conversion Eff i ciency

85% ≤

Class

Project

Specifications

INTPU T

D C input

PD bidirectional 20V / 3A 60W

ACOUT 220V

A C output voltage

1 A C socket A C220V ±  5%

A C output power

100W

A C output over power protection

A bout 120W

A C output waveform

Correction wave

A C output peak

200W peak maintenance time < 50ms

Frequency

50H z

USB output port

U sb1 output

5V /2A (Total3

U SB 2 output

QC3.0 M A X 12V /1.5A

Electric core

type

Ternary l i thium cell 21700 / 4000m A h

capacity

24000m A H (3S2P)

power

88WH

cycle l i fe

M ore than 1000 times

Charging parameters

 

PD 60W

Charging time

2.5-3.5H

Charge f rom 0% to 100% (automatic cut-off)

Full voltage

12.55V ± 0.1V

The battery i s charged to the voltage at automatic cut-off

LCD display

D i splay the power, charge and stop charge status

The power column f lashes, PD + in, and the power

column i s always on

D C, A C and inverter status

Switch status of U SB QC 3.0 and A C

Static self power consumption

 

<700uA

 

No load sleep

A C no load

The AC output will be automatically turned off after 1 minute

D C no load

When the AC i s not turned on, it will automatically enter sleep for one minute

Protection function

 

Short circuit, overload, overtemperature, overvoltage, overcurrent, undervoltage, etc

 

The display will flash three times and turn off the AC symbol

I nverter over temperature protection

Over temperature protection

≥ 100℃

Over temperature recovery

≤ 80℃