It is composed of three-element circuit board, s2dc inverter circuit board and 3P battery protection circuit board. Inverter 100W correction wave AC220V/ 50Hz, subject to pure resistance load,USB port 5V/ 2A (total). It is suitable for camping, emergency communication,medical rescue, fire rescue and other fields.
It is composed of three-element circuit board, s2dc inverter circuit board and 3P battery protection circuit board. Inverter 100W correction wave AC220V/ 50Hz, subject to pure resistance load,USB port 5V/ 2A (total). It is suitable for camping, emergency communication,medical rescue, fire rescue and other fields.
Precautions for Product Operation
● Strictly follow the operation steps of the product.
● For the heat dissipation space of the product, 5cm space is reserved around the product to make the heat dissipation convective.
● When the power of the product is insufficient, the load power exceeds the rated power or the ambient temperature is too high, the product will automatically start the protection function and turn off the output.
● For power charging, it is recommended to charge without load.
● If the power supply is not used for a long time, the power supply itself will be exhausted. Please make sure to charge it every 6 months.
● It is forbidden to use this product in flammable, explosive and corrosive gas environment such as gasoline and gas.
● If the product is accidentally flooded or invaded by other foreign substances, please send it to the Distribution Office for testing and treatment as soon as possible to ensure the safe use of the product. If it is caused by abnormal use, the company will charge for treatment according to the actual situation.
Specification
Model |
PPS100 |
|
Capacity |
5000m A h * 3 Series 2 parallel |
|
Cell |
21700/4000mA h 0.5C |
|
B attery Power |
88W H |
|
A C Power |
Correction wave A C 220V / 50H z |
|
A C Peak V alue |
200W peak maintenance time < 50ms |
|
Conversion Eff i ciency |
85% ≤ |
|
Class |
Project |
Specifications |
INTPU T |
D C input |
PD bidirectional 20V / 3A 60W |
ACOUT 220V |
A C output voltage |
1 A C socket A C220V ± 5% |
A C output power |
100W |
|
A C output over power protection |
A bout 120W |
|
A C output waveform |
Correction wave |
|
A C output peak |
200W peak maintenance time < 50ms |
|
Frequency |
50H z |
|
USB output port |
U sb1 output |
5V /2A (Total3 |
U SB 2 output |
QC3.0 M A X 12V /1.5A |
|
Electric core |
type |
Ternary l i thium cell 21700 / 4000m A h |
capacity |
24000m A H (3S2P) |
|
power |
88WH |
|
cycle l i fe |
M ore than 1000 times |
|
Charging parameters |
|
PD 60W |
Charging time |
2.5-3.5H |
Charge f rom 0% to 100% (automatic cut-off) |
Full voltage |
12.55V ± 0.1V |
The battery i s charged to the voltage at automatic cut-off |
LCD display |
D i splay the power, charge and stop charge status |
The power column f lashes, PD + in, and the power column i s always on |
D C, A C and inverter status |
Switch status of U SB QC 3.0 and A C |
|
Static self power consumption |
|
<700uA |
No load sleep |
A C no load |
The AC output will be automatically turned off after 1 minute |
D C no load |
When the AC i s not turned on, it will automatically enter sleep for one minute |
|
Protection function |
|
Short circuit, overload, overtemperature, overvoltage, overcurrent, undervoltage, etc |
|
The display will flash three times and turn off the AC symbol |
|
I nverter over temperature protection |
Over temperature protection |
≥ 100℃ |
Over temperature recovery |
≤ 80℃ |
Precautions for Product Operation
● Strictly follow the operation steps of the product.
● For the heat dissipation space of the product, 5cm space is reserved around the product to make the heat dissipation convective.
● When the power of the product is insufficient, the load power exceeds the rated power or the ambient temperature is too high, the product will automatically start the protection function and turn off the output.
● For power charging, it is recommended to charge without load.
● If the power supply is not used for a long time, the power supply itself will be exhausted. Please make sure to charge it every 6 months.
● It is forbidden to use this product in flammable, explosive and corrosive gas environment such as gasoline and gas.
● If the product is accidentally flooded or invaded by other foreign substances, please send it to the Distribution Office for testing and treatment as soon as possible to ensure the safe use of the product. If it is caused by abnormal use, the company will charge for treatment according to the actual situation.
Specification
Model |
PPS100 |
|
Capacity |
5000m A h * 3 Series 2 parallel |
|
Cell |
21700/4000mA h 0.5C |
|
B attery Power |
88W H |
|
A C Power |
Correction wave A C 220V / 50H z |
|
A C Peak V alue |
200W peak maintenance time < 50ms |
|
Conversion Eff i ciency |
85% ≤ |
|
Class |
Project |
Specifications |
INTPU T |
D C input |
PD bidirectional 20V / 3A 60W |
ACOUT 220V |
A C output voltage |
1 A C socket A C220V ± 5% |
A C output power |
100W |
|
A C output over power protection |
A bout 120W |
|
A C output waveform |
Correction wave |
|
A C output peak |
200W peak maintenance time < 50ms |
|
Frequency |
50H z |
|
USB output port |
U sb1 output |
5V /2A (Total3 |
U SB 2 output |
QC3.0 M A X 12V /1.5A |
|
Electric core |
type |
Ternary l i thium cell 21700 / 4000m A h |
capacity |
24000m A H (3S2P) |
|
power |
88WH |
|
cycle l i fe |
M ore than 1000 times |
|
Charging parameters |
|
PD 60W |
Charging time |
2.5-3.5H |
Charge f rom 0% to 100% (automatic cut-off) |
Full voltage |
12.55V ± 0.1V |
The battery i s charged to the voltage at automatic cut-off |
LCD display |
D i splay the power, charge and stop charge status |
The power column f lashes, PD + in, and the power column i s always on |
D C, A C and inverter status |
Switch status of U SB QC 3.0 and A C |
|
Static self power consumption |
|
<700uA |
No load sleep |
A C no load |
The AC output will be automatically turned off after 1 minute |
D C no load |
When the AC i s not turned on, it will automatically enter sleep for one minute |
|
Protection function |
|
Short circuit, overload, overtemperature, overvoltage, overcurrent, undervoltage, etc |
|
The display will flash three times and turn off the AC symbol |
|
I nverter over temperature protection |
Over temperature protection |
≥ 100℃ |
Over temperature recovery |
≤ 80℃ |